asecos Catalogue 2013/14

UFA-LINE

UFA-LINE

Recirculating air filter system UFA.20.30-AUS for underbench cabinets

Recirculating air filter system – avoid complex wall and ceiling openings and expensive exhaust air ducts

Safe capturing of escaping vapours at the point where they are released or produced

• high flexibility in choosing the installation location • active personal protection through safe capture of harmful vapours with retention in the filter system • very low noise, only approx. 39 dB (A) • ATEX complient: CE II 3/-G Ex ic nA IIB T4 Gc • housing made of sheet-steel plastic laminated • with multistage filter system and power cord • incl. VDE tested extraction and filter monitoring • optical and acoustical alarm including potential-free alarm contact • dimensions W x D x H (mm): 305 x 555 x 210 The plug-in recirculating air filter system UFA.20.30 is capable of retaining solvent vapours (hydrocarbons) permanently up to a filter saturation of more than 99,999 %, under normal operating conditions as well as for a simulated accident in the safety storage cabinet A special version of the recirculating air filter system is also available to meet the pressure and volumetric flow conditions inside XL-LINE Drum Cabinets (further details see page 184-189)

The recirculating air filter system UFA.20.30-AUS was especially designed for the pressure conditions and volumetric flows of safety storage cabinets with a small internal volume. It can be installed on a wall bracket (illustration on right) or in a convenient housing unit (illustration below).

Option 1: wall bracket for installation on a wall Order No. 23458 n

Recirculating air filter system UFA.20.30 Order No. 25099 n

The asecos recirculating air filter system – successfully tested and certified by the testing institute

Technical data

Motor rating

kW

0.03 230

Nominal voltage

V

Frequency

Hz

50

Input current Noise level Revolutions

A

0.13

dB (A)

39

Recirculating air filter system according to 2006/95/EG (Low Voltage directive) marking CE II 3/-G Ex ic nA IIB T4 Gc conform with the EMC Directive RL 2004/108/EG and RL 94/9/EG (ATEX Directive)

rpm

2450

Activated carbon filter weight (incl. filling 3500 g) Volumetric flow (mounted on the cabinet)

kg

4.2

ca. 25 m 3 /h

Load capacity of the voltage-free alarm contact

Maximum nominal voltage: AC 230 V ~ Maximum nominal voltage: DC 48 V Maximum switching current: 1A

Option 2: Recirculating air filter system UFA.20.30-AUS with housing unit (without underbench cabinet) Order No. 27318 n

Please attend to your country specific terms of use.

Please attend to your country specific terms of use.

Article

Order No. 25099 n 27887 n

Article

Order No. 27144 n

Recirculating air filter system UFA.20.30 Recirculating air filter system UFA.20.30-XL for drum cabinets

Recirculating air filter system UFA.20.30-AUS

Accessories Wall bracket, suitable for installation on a wall for UFA.20.30-AUS

23458 n

Accessories Replacement filter for UFA.20.30

Article Recirculating air filter system UFA.20.30-AUS with housing unit for asecos underbench cabinets

24212 n 15776 n

27318 n

Adapter for drum cabinets

Accessories for both articles Replacement filter for UFA.20.30-AUS

24212 n

277

276

Ready for dispatch within n 2 days