asecos Catalogue 2013/14

Fans

Air Exhaust Monitoring

Fans – powerful and safe

Air exhaust monitoring - safe and easy monitoring of air exhaust - quick installation

Radial fan CE II 3G c II B T4 x 07 ATEX D105 Order No. 5793 n

• housing and impeller made of polypropylene • sealed against gas emission

Safe and easy monitoring of exhaust air out of a cabinet

• connecting fitting 75 NW • VDMA and CE conformal • protection class IP 55 • air flow 60-250 m 3 /h • total pressure 240-175 Pa • incl. PA/GFK console

Air exhaust and volume flow monitoring • with connection cable (3 m) and power cord • mounting between cabinet and on-site air exhaust-system • connecting fitting 75 NW • dimensions W x D x H (mm): 300 x 400 x 265

• ready to plug-in, quick installation • ATEX complient: CE II 3/-G c T4

Model BASIC-LINE • electro-pneumatic air exhaust monitoring • minimum volume flow 30 m 3 /h Model COFORT-LINE • electronic volume flow monitoring • minimum volume flow 20 m 3 /h Model HIGH-LINE • electronic volume flow monitoring • minimum volume flow 20 m 3 /h • potential-free alarm contact • localisation of cabinet’s or on-site dysfunction

Motor protection switch suitable for fans Order No. 5799 n

Housing for the motor protection switch (without illustration) Order No. 5803 n

Air exhaust monitoring BASIC-LINE Model APG.26.30-BL Order No. 14945 n

Model EXCLUSIVE-LINE • electronic volume flow monitoring • minimum volume flow 20 m 3 /h • potential-free alarm contact

Flexible hose made of plastic, Ø 75 mm (inner diameter) Order No. 1434 n

Technical data

5793

5794

Motor rating (kW) Nominal voltage (V) Frequency (Hz) Current input (A) Noise level dB (A) Revolutions (rpm)

0.09

0.09

1 × 230

3 × 400

• localisation of cabinet’s or on-site dysfunction • digital display of the exact volume flow and acoustic alarm in case of power breakdown

50

50

0.35

0.33

45

45

2850

2800

T-piece made of PVC, Ø 75 mm (outer diameter) Order No. 8681 n

Radial fan, EX-proof CE ll 2G c llB T4 PTB07 ATEX D105 Order No. 5794 n

Volume flow monitoring High-Line Model APG.26.30-HL Order No. 14371 n

Volume flow monitoring Exclusive-Line Model APG.26.30-EL Order No. 14352 n

Butterfly damper made of plastic, Ø 75 mm (outer diameter) Order No. 5798 n

Technical data

APG.26.30-BL

APG.26.30-CL

APG.26.30-HL

APG.26.30-EL

Nominal voltage (V) Frequency (Hz) Input current (A) Noise level dB (A)

230

230

230

230

50

50

50

50

0.11 <28

0.15 <28

0.15 <28

0.15 <28

Extraction air amount (m 3 /h)

30 20

20

20

20

Pressure drop (Pa)

5

5

5

Hose clamp made of chrome steel, Ø 70 - 90 mm Order No. 5797 n

Article

APG.26.30-BL

APG.26.30-CL

APG.26.30-HL

APG.26.30-EL

Order No.

14945 n

14372 n

14371 n

14352 n

281

280

Ready for dispatch within n 6 weeks

Ready for dispatch within n 2 days

281

Made with